Provides repeatable, accurate measurement of breakdown voltage of insulating oils used in electrical equipment./ Versatile, lightweight and rugged./ Designed for both field and laboratory use./ Three rates of rise, 500V/2000V/3000V per second./ Rate of rise selector switch with Stop/Dwell positions./ Arc detection with automatic shutdown./ 'Zero Start' and test chamber interlock provision./ Window panel for test observation./ 60 kV & 100 kV test cells for ASTM & IEC standards./
Newest and most complete design for an automatic programmable liquid dielectric tester./Preprogrammed test sequences./User programmable test routines./Internal memory./Computer interface./Built-in printer./Many languages available./Provides repeatable, accurate measurement of breakdown voltage of insulating oils used in electrical equipment./Versatile, lightweight and rugged./Designed for both field and laboratory use
Provides repeatable, accurate measurement of breakdown voltage of insulating oils used in electrical equipment./Versatile, lightweight and rugged./Designed for both field and laboratory use./Three rates of rise, 500V/2000V/3000V per second./Rate of rise selector switch with Stop/Dwell positions./Arc detection with automatic shutdown./'Zero Start' and test chamber interlock provision,/Window panel for test observation./60 kV & 100 kV test cells for ASTM & IEC standards
Continuously adjustable output voltage./ ''Zero Start'' Interlock./ Adjustable overcurrent trip point from 10%-100% of each current range./ Large, easy to read, high accuracy digital meters./ Analog 0-100% of range current meter for visual charge indication./ Input circuit breaker / power switch./ Thermal resettable overload./ Built in discharge circuit./ Integrated cable storage bin./ Removable line cord./ Light weight, portable and enclosed in rugged, high density polyethylene carrying case.
Continuously adjustable output voltage./ ''Zero Start'' Interlock./ Adjustable overcurrent trip point from 10%-100% of each current range./ Large, easy to read, high accuracy digital meters./ Analog 0-100% of range current meter for visual charge indication./ Input circuit breaker / power switch./ Thermal resettable overload./ Built in discharge circuit./ Integrated cable storage bin./ Removable line cord./ Light weight, portable and enclosed in rugged, high density polyethylene carrying case.
Continuously adjustable output voltage./ ''Zero Start'' Interlock./ Adjustable overcurrent trip point from 10%-100% of each current range./ Large, easy to read, high accuracy digital meters./ Analog 0-100% of range current meter for visual charge indication./ Input circuit breaker / power switch./ Thermal resettable overload./ Built in discharge circuit./ Integrated cable storage bin./ Removable line cord./ Light weight, portable and enclosed in rugged, high density polyethylene carrying case.
Continuously adjustable output voltage./ ''Zero Start'' Interlock./ Adjustable overcurrent trip point from 10%-100% of each current range./ Large, easy to read, high accuracy digital meters./ Analog 0-100% of range current meter for visual charge indication./ Input circuit breaker / power switch./ Thermal resettable overload./ Built in discharge circuit./ Integrated cable storage bin./ Removable line cord./ Light weight, portable and enclosed in rugged, high density polyethylene carrying case.
Continuously adjustable output voltage./ ''Zero Start'' Interlock./ Adjustable overcurrent trip point from 10%-100% of each current range./ Large, easy to read, high accuracy digital meters./ Analog 0-100% of range current meter for visual charge indication./ Input circuit breaker / power switch./ Thermal resettable overload./ Built in discharge circuit./ Integrated cable storage bin./ Removable line cord./ Light weight, portable and enclosed in rugged, high density polyethylene carrying case.
Metal enclosure with provision for ground lead./ External interlock provision./ Zero-start interlock./ Input circuit breaker with indicator./ Overload circuit adjustable by means of a potentiometer from 10 to 110% of rated current; includes reset button with indicator./ HV ON momentary pushbutton with indicator./ Single range analog voltmeter connected across the output for maximum accuracy...
Metal enclosure with provision for ground lead./ External interlock provision./ Zero-start interlock./ Input circuit breaker with indicator./ Overload circuit adjustable by means of a potentiometer from 10 to 110% of rated current; includes reset button with indicator./ HV ON momentary pushbutton with indicator./ Single range analog voltmeter connected across the output for maximum accuracy./ Single range analog currentmeter connected directly in the return/ground leg for maximum accuracy./
Metal enclosure with provision for ground lead./ External interlock provision./ Zero-start interlock./ Input circuit breaker with indicator./ Overload circuit adjustable by means of a potentiometer from 10 to 110% of rated current; includes reset button with indicator./ HV ON momentary pushbutton with indicator./ Single range analog voltmeter connected across the output for maximum accuracy./ Single range analog currentmeter connected directly in the return/ground leg for maximum accuracy.
Metal enclosure with provision for ground lead./ External interlock provision./ Zero-start interlock./ Input circuit breaker with indicator./ Overload circuit adjustable by means of a potentiometer from 10 to 110% of rated current; includes reset button with indicator./ HV ON momentary pushbutton with indicator./ Single range analog voltmeter connected across the output for maximum accuracy./ Single range analog currentmeter connected directly in the return/ground leg for maximum accuracy./
Metal enclosure with provision for ground lead./ External interlock provision./ Zero-start interlock./ Input circuit breaker with indicator./ Overload circuit adjustable by means of a potentiometer from 10 to 110% of rated current; includes reset button with indicator./ HV ON momentary pushbutton with indicator./ Single range analog voltmeter connected across the output for maximum accuracy./ Single range analog currentmeter connected directly in the return/ground leg for maximum accuracy./
Metal enclosure with provision for ground lead./ External interlock provision./ Zero-start interlock./ Input circuit breaker with indicator./ Overload circuit adjustable by means of a potentiometer from 10 to 110% of rated current; includes reset button with indicator./ HV ON momentary pushbutton with indicator./ Single range analog voltmeter connected across the output for maximum accuracy./ Single range analog currentmeter connected directly in the return/ground leg for maximum accuracy.
Metal enclosure with provision for ground lead./ External interlock provision./ Zero-start interlock./ Input circuit breaker with indicator./ Overload circuit adjustable by means of a potentiometer from 10 to 110% of rated current; includes reset button with indicator./ HV ON momentary pushbutton with indicator./ Single range analog voltmeter connected across the output for maximum accuracy./ Single range analog currentmeter connected directly in the return/ground leg for maximum accuracy.
Metal enclosure with provision for ground lead./ External interlock provision./ Zero-start interlock./ Input circuit breaker with indicator./ Overload circuit adjustable by means of a potentiometer from 10 to 110% of rated current; includes reset button with indicator./ HV ON momentary pushbutton with indicator./ Single range analog voltmeter connected across the output for maximum accuracy./ Single range analog currentmeter connected directly in the return/ground leg for maximum accuracy.
Metal enclosure with provision for ground lead./ External interlock provision./ Zero-start interlock./ Input circuit breaker with indicator./ Overload circuit adjustable by means of a potentiometer from 10 to 110% of rated current; includes reset button with indicator./ HV ON momentary pushbutton with indicator./ Single range analog voltmeter connected across the output for maximum accuracy./ Single range analog currentmeter connected directly in the return/ground leg for maximum accuracy.
Metal enclosure with provision for ground lead./ External interlock provision./ Zero-start interlock./ Input circuit breaker with indicator./ Overload circuit adjustable by means of a potentiometer from 10 to 110% of rated current; includes reset button with indicator./ HV ON momentary pushbutton with indicator./ Single range analog voltmeter connected across the output for maximum accuracy./ Single range analog currentmeter connected directly in the return/ground leg for maximum accuracy.
Metal enclosure with provision for ground lead./ External interlock provision./ Zero-start interlock./ Input circuit breaker with indicator./ Overload circuit adjustable by means of a potentiometer from 10 to 110% of rated current; includes reset button with indicator./ HV ON momentary pushbutton with indicator./ Single range analog voltmeter connected across the output for maximum accuracy./ Single range analog currentmeter connected directly in the return/ground leg for maximum accuracy.
Metal enclosure with provision for ground lead./ External interlock provision./ Zero-start interlock./ Input circuit breaker with indicator./ Overload circuit adjustable by means of a potentiometer from 10 to 110% of rated current; includes reset button with indicator./ HV ON momentary pushbutton with indicator./ Single range analog voltmeter connected across the output for maximum accuracy./ Single range analog currentmeter connected directly in the return/ground leg for maximum accuracy.
Metal enclosure with provision for ground lead./ External interlock provision./ Zero-start interlock./ Input circuit breaker with indicator./ Overload circuit adjustable by means of a potentiometer from 10 to 110% of rated current; includes reset button with indicator./ HV ON momentary pushbutton with indicator./ Single range analog voltmeter connected across the output for maximum accuracy./ Single range analog currentmeter connected directly in the return/ground leg for maximum accuracy.
Metal enclosure with provision for ground lead./ External interlock provision./ Zero-start interlock./ Input circuit breaker with indicator./ Overload circuit adjustable by means of a potentiometer from 10 to 110% of rated current; includes reset button with indicator./ HV ON momentary pushbutton with indicator./ Single range analog voltmeter connected across the output for maximum accuracy./ Single range analog currentmeter connected directly in the return/ground leg for maximum accuracy.
High accuracy: +/- 1% of FS/Ruggedly constructed case/Lightweight/Portable/Zero start (safety interlock feature)/Output termination: Toroid with output lead/Adjustable overcurrent trip from 10% to 110% of rating/Internal Short circuit protection/50 kV AC hipot, multi-purpose, rugged design test breakers, switchgear and many other apparatus/40 mA of output current independent of test specimen type (resistive or capacitive)/Two piece construction/External interlock provision
High accuracy: +/- 1% of FS/Ruggedly constructed case/Lightweight/Portable/Zero start (safety interlock feature)/Output termination: Toroid with output lead/Adjustable overcurrent trip from 10% to 110% of rating/Internal Short circuit protection/50 kV AC hipot, multi-purpose, rugged design test breakers, switchgear and many other apparatus/40 mA of output current independent of test specimen type (resistive or capacitive)/Two piece construction/External interlock provision
60kV AC Hipot designed for field use primarily for vacuum bottle testing, however, it can be used for testing breakers, switchgear and many other apparatus/Tests up to 24.9 kV class interrupters in accordance with ANSI/IEEE C37.60 specifications/Portable two-piece unit /Digital dwell timer/Selectable rate of voltage rise (500 volts/sec, 3000 volts/sec...
Features: Pre-settable over voltage and over current trip point. Memory voltmeter. Main Circuit Breaker. Graphic Interface Display. Transparent doors with high voltage interlock. Fast-acting overload protection. Easily mobile, crane forklifting design provisions. Isolated RS-232 port for computer data acquisition and control.
Features: Pre-settable over voltage and over current trip point. Memory voltmeter. Main Circuit Breaker. Graphic Interface Display. Transparent doors with high voltage interlock. Fast-acting overload protection. Easily mobile, crane forklifting design provisions. Isolated RS-232 port for computer data acquisition and control.
Features: Pre-settable over voltage and over current trip point. Memory voltmeter. Main Circuit Breaker. Graphic Interface Display. Transparent doors with high voltage interlock. Fast-acting overload protection. Easily mobile, crane forklifting design provisions. Isolated RS-232 port for computer data acquisition and control.
Features: Pre-settable over voltage and over current trip point. Memory voltmeter. Main Circuit Breaker. Graphic Interface Display. Transparent doors with high voltage interlock. Fast-acting overload protection. Easily mobile, crane forklifting design provisions. Isolated RS-232 port for computer data acquisition and control.
Designed specifically for AC dielectric testing./ For those performing testing that requires transmission and distribution level boom testing but not lining testing./ Economical choice./ Internal Voltage dividers for all units./ Controls in a removable enclosure, grounded through the powercord with provisions for a separate ground cable./ Circuit breaker for control power, combined with EMERGENCY OFF pushbutton./ Guard mode for accurate current measurements./ External interlock provisions./ ZERO START interlock./ Overload circuit, adjustable from 10% to 110% of rated output current./ CONTROL POWER ON indicator./ HV ON/OFF pushbuttons with indicator./ Manual control of output voltage./ Resettable OVERLOAD indicator./ 20 ft. interconnect cables between controls and high voltage unit./ Grounding studs on control panel and high voltage transformer./ 20 Ft. ground and return leads./ Cable storage provision./ Two copies of Operation / Maintenance Manual./ Optional cart mounted, telexcoping red flashing light high voltage warning indicator .
Designed specifically for AC dielectric testing./ Powerful unit with output current sufficient to test both the elevating boom as well as the insulated work platfrom and linings./ Internal Voltage dividers for all units./ Controls in a removable enclosure, grounded through the powercord with provisions for a separate ground cable./ Circuit breaker for control power, combined with EMERGENCY OFF pushbutton./ Guard mode for accurate current measurements./ External interlock provisions./ ZERO START interlock./ Overload circuit, adjustable from 10% to 110% of rated output current.
Designed specifically for AC dielectric testing./ Economical solution for boom testing on distribution level devices./ Internal Voltage dividers for all units./ Controls in a removable enclosure, grounded through the powercord with provisions for a separate ground cable./ Circuit breaker for control power, combined with EMERGENCY OFF pushbutton./ Guard mode for accurate current measurements./ External interlock provisions./ ZERO START interlock./ Overload circuit, adjustable from 10% to 110% of rated output current.
Precision accuracy and lasting reliability./ Portable, rugged unit for field or laboratory testing./ Includes a high voltage divider, metering section and interconnect cables which fasten into a compact, durable case./ Battery powered, or with standard line voltages./ Traceable to NIST standards./ Can be used for calibration, voltage monitoring, of high voltage systems and DC power supplies./ Voltage divider can also be used with other measuring devices such as an oscilloscope./ Battery powered units can be CE marked.
Precision accuracy and lasting reliability./ Portable, rugged unit for field or laboratory testing./ Includes a high voltage divider, metering section and interconnect cables which fasten into a compact, durable case./ Battery powered, or with standard line voltages./ Traceable to NIST standards./ Can be used for calibration, voltage monitoring, of high voltage systems and DC power supplies./ Voltage divider can also be used with other measuring devices such as an oscilloscope./ Battery powered units can be CE marked.
Phenix Technologies Liquid Dielectric Test Sets are designed to measure the breakdown voltage of insulation fluids used in transformers, capacitors, bushings and related high voltage equipment. The units are portable and may be used for either on-site or laboratory testing. Three standard models rated at 60, 75 and 100 kV are available.
Phenix Technologies Liquid Dielectric Test Sets are designed to measure the breakdown voltage of insulation fluids used in transformers, capacitors, bushings and related high voltage equipment. The units are portable and may be used for either on-site or laboratory testing. Three standard models rated at 60, 75 and 100 kV are available.
Phenix Technologies Liquid Dielectric Test Sets are designed to measure the breakdown voltage of insulation fluids used in transformers, capacitors, bushings and related high voltage equipment. The units are portable and may be used for either on-site or laboratory testing. Three standard models rated at 60, 75 and 100 kV are available.
Integral megohmmeter measures insulation resistance up to 500,000 megohms @ 2.5kVDC or up to 1,000,000 megohms @ 5.0kVDC./ Voltage output continuously adjustable up to 5,000 VAC or 6,000VDC./ Zero Start voltage interlock./ Leakage current measurements from 0.1 to 5,000 microamps DC and from 1.0 to 5.0 milliamps AC./ Adjustable overcurrent trip point./ Large, easy-to-read analog meters./ Rotary switch selection simplifies operation./ Light weight, portable and enclosed in a rugged high density polyethylene carrying case.
Lightweight, portable, and enclosed in a rugged carrying case./ Large, easy to read meters./ Adjustable overcurrent trip point./ Continuously adjustable output./ Guard circuit for stray leakage current bypass./ Surge and transient protection, 10' output leads./ External interlock provision./ Zero Start Interlock./ HV ON/OFF pushbuttons with indicators./ Direct megohm readings./ Visual and audible overload indicator./ 3 range voltmeter, 4 range ammeter.
Microprocessor-based./ Automatic./ Single and 3 Phase./ Portable./ Lightweight./ Rugged./ Self-Calibrates before each measurement./ Also measures excitation current and phase angle./ 20 charachter x 4 line back-lighted LCD display./ Results can be printed immediately on a built in 4.5 inch thermal printer./ Store up to 200 transformer test records in Flash EEPROM, reach record may contain up to 99 ratio, excitation current, phase angle, and nameplate voltage readings./ Downloadable to PC (Windows based software package included./ Able to create a test plan for a specific transformer.