Phenix Technologies BK130 -1 Aerial Lift Test Kit Set - 130 k VAC output

Designed specifically for AC dielectric testing./ For those performing testing that requires transmission and distribution level boom testing but not lining testing./ Economical choice./ Internal Voltage dividers for all units./ Controls in a removable enclosure, grounded through the powercord with provisions for a separate ground cable./ Circuit breaker for control power, combined with EMERGENCY OFF pushbutton./ Guard mode for accurate current measurements./ External interlock provisions./ ZERO START interlock./ Overload circuit, adjustable from 10% to 110% of rated output current./ CONTROL POWER ON indicator./ HV ON/OFF pushbuttons with indicator./ Manual control of output voltage./ Resettable OVERLOAD indicator./ 20 ft. interconnect cables between controls and high voltage unit./ Grounding studs on control panel and high voltage transformer./ 20 Ft. ground and return leads./ Cable storage provision./ Two copies of Operation / Maintenance Manual./ Optional cart mounted, telexcoping red flashing light high voltage warning indicator .
Nhà sản xuất: Phenix Technologies
SKU: BK130-1
Mã hàng (Model): BK130-1
100 đ

Phenix Technologies BK130-1 Aerial Lift Test Kit Set - 130 k VAC output

Features:
  • Designed specifically for AC dielectric testing
  • For those performing testing that requires transmission and distribution level boom testing but not lining testing
  • Economical choice
  • Internal Voltage dividers for all units
  • Controls in a removable enclosure, grounded through the powercord with provisions for a separate ground cable
  • Circuit breaker for control power, combined with EMERGENCY OFF pushbutton
  • Guard mode for accurate current measurements
  • External interlock provisions
  • ZERO START interlock
  • Overload circuit, adjustable from 10% to 110% of rated output current
  • CONTROL POWER ON indicator
  • HV ON/OFF pushbuttons with indicator
  • Manual control of output voltage
  • Resettable OVERLOAD indicator
  • 20 ft. interconnect cables between controls and high voltage unit
  • Grounding studs on control panel and high voltage transformer
  • 20 Ft. ground and return leads
  • Cable storage provision
  • Two copies of Operation / Maintenance Manual
  • Optional cart mounted, telexcoping red flashing light high voltage warning indicator
Technical Specs:
  • Input: 120 volts, 15 amps, 50-60 Hz, single phase or 220 volts, 8 amps, 50-60 Hz, single phase
  • Output: 0-130k VAC@ 11.7mA
  • Duty: 1 hour ON / 1 hour OFF @ 8.33mA, 5 min ON / 15 min OFF @ 11.7mA, Continuous @ 5.6mA
  • Voltmeter: Single range digital with accuracy of 1% reading: 12-130kV
  • Voltmeter Range: 0-130 kVAC
  • Currentmeter: Triple-range digital with accuracy +/- 1% FS
  • Currentmeter Range: Four range 0-200µA, 2mA, 20mA
Tag sản phẩm