Phenix Technologies PATTR-03 3 Phase Transformer Turns Ratio Test Set

Microprocessor-based./ Automatic./ Single and 3 Phase./ Portable./ Lightweight./ Rugged./ Self-Calibrates before each measurement./ Also measures excitation current and phase angle./ 20 charachter x 4 line back-lighted LCD display./ Results can be printed immediately on a built in 4.5 inch thermal printer./ Store up to 200 transformer test records in Flash EEPROM, reach record may contain up to 99 ratio, excitation current, phase angle, and nameplate voltage readings./ Downloadable to PC (Windows based software package included./ Able to create a test plan for a specific transformer.
Nhà sản xuất: Phenix Technologies
SKU: PATTR-03
Mã hàng (Model): PATTR-03
100 đ
Features:
  • Microprocessor-based
  • Automatic
  • Single and 3 Phase
  • Portable
  • Lightweight
  • Rugged
  • Self-Calibrates before each measurement
  • Also measures excitation current and phase angle
  • 20 charachter x 4 line back-lighted LCD display
  • Results can be printed immediately on a built in 4.5 inch thermal printer
  • Store up to 200 transformer test records in Flash EEPROM, reach record may contain up to 99 ratio, excitation current, phase angle, and nameplate voltage readings
  • Downloadable to PC (Windows based software package included
  • Able to create a test plan for a specific transformer
Specs:
  • Dimensions: 17''Lx13''Wx7''H
  • Weight: 14 lbs
  • Power: 120/240 VAC, 50/60 Hz
  • Ratio-Measuring Ranges: 0.8 to 15,000
  • Turns-Ratio Accuracy:
    • 0.8-1999 +/- 0.1%, 2000-3999 +/- 0.25%, 4000-15,000 +/- 1% @ 8 VAC
    • 0.8-1999 +/- 0.1%, 2000-3999 +/- 0.20%, 4000-15,000 +/- 1% @ 40 VAC
    • 0.8-1999 +/- 0.1%, 2000-3999 +/- 0.15%, 4000-15,000 +/- 1% @ 100 VAC
  • Calibration: None required
  • Excitation Voltage: 8VAC, 40VAC, 100VAC
  • Current Accuracy:+/- 2% of reading (+/- 1 digit)
  • Phase Angle Measurement: 0-360 Degrees
  • Phase Angle Accuracy: +/- 0.2 Degree (+/- 1 digit)
  • Computer Interface: RS-232C, 19,2000 baud
  • PC Software: Windows-based, included
  • Test Storage: 200 complete transformer test records. Each test record includes nameplate voltage, winding turns ratio, excitation current, and winding phase angle. Data can be retained for 2 years
  • Temperature:
    • Operating: -10°C to 50°C (15°F to +122°F)
    • Storage: -30°C to 70°C (-22°F to +158°F)
  • Cables:
    • One 15 ft (5m) single-phase cable set
    • One 15 ft (5m) three-phase cable set
    • One 30 ft (10m) extension cable set
    • One input power cord
    • One ground lead
    • One cable-carrying bag included