Function | 1 Stage Preset Counter,2 Stage Preset Counter,Total Preset Counter,Batch Counter,Dual Counter,Tachometer |
---|
Preset stages | 2 stage |
---|
Rated supply voltage | 100 to 240 VAC 50/60 Hz |
---|
Operating voltage range | 85% to 110% of rated supply voltage |
---|
Power consumption | Approx. 9.4 VA (at 264 VAC) |
---|
External power supply | 12 VDC(+-10%) 100 mA |
---|
Counter (Count range) | -99999 to 999999 |
---|
Counter (Max. counting speed) | 30 Hz/5 kHz(switching) Minimum counting input signal width: 16.7 ms(ON/OFF ratio: 1:1)/0.1 ms(ON/OFF ratio: 1:1) Common setting for CP1 and CP2 |
---|
Counter (Input mode) | Increment decrement or increment/decrement (UP/DOWN A (command input), UP/DOWN B (individual input) and UP/DOWN C(quadrature input)) |
---|
Counter (Output modes) | N, F, C, R, K-1, P, Q, A, K-2, D, L, H |
---|
Counter (One-shot time) | 0.01 to 99.99 s variable |
---|
Counter (Reset system) | External, manual and automatic reset (internal according to C,R,P and Q mode operation) |
---|
Tachometer (Input mode) | Independent measurements for 1 or 2 inputs, differential input for 2 inputs, absolute ratio for 2 inputs, and error ratio for 2 inputs. (selectable) |
---|
Tachometer (Pulse measurement method) | Periodic measurement Pulse width measurement |
---|
Tachometer (Sampling period) | Periodic measurement: 200 ms Pulse width measurement: Continuous (minimum interval of 10 ms) |
---|
Tachometer (Max. counting speed) | Periodic measurement: 30 Hz / 10 kHz (selectable)(30 Hz / 5 kHz (selectable) at except 1-input mode) Pulse width measurement: 30 Hz / 10 kHz (selectable)(30 Hz / 5 kHz (selectable) at except 1-input mode) |
---|
Tachometer (Count range) | 0 to 999999 |
---|
Tachometer (Measuring ranges) | Periodic measurement: 30 Hz: 0.01 Hz to 30.00 Hz / 10 kHz: 0.01 Hz to 10 kHz (0.01 Hz to 5 kHz at except 1-input mode) 30 Hz: 0.030 to 999999 s / 10 kHz: 0.0002 to 999999 s (0.0004 to 999999 s at except 1-input mode) |
---|
Tachometer (Minimum input signal width) | 30 Hz: 30 ms / 10 kHz: 0.2 ms (0.4 ms at except 1-input mode) |
---|
Tachometer (Measuring accuracy) | +-0.1%F.S.+-1 digit max. (at 23+-5CEL) |
---|
Tachometer (Output modes) | Except 2-input individual measurement: Upper and lower limit/ area/ upper limit/ lower limit 2-input individual measurement: Upper limit/ lower limit |
---|
Tachometer (Auto-zero time) | 0.1 to 999.9 s |
---|
Tachometer (Startup time) | 0.0 to 99.9 s |
---|
Tachometer (Average processing) | OFF/ 2 times/ 4 times/ 8 times |
---|
Input signal | CP1 ,CP2 ,Reset1 ,Reset2 |
---|
Input method | No-voltage/Voltage input(selectable) |
---|
No-voltage input (No-contact input) | Short-circuit (ON) impedance: 1 kOhm max. Leakage current(0 ohm): Approx. 12 mA Residual voltage: 3 V max. Open circuit impedance: 100 kOhm min. Maximum voltage: 30 VDC max. |
---|
No-voltage input (Contact input) | Use a contact which can adequately switch 5 mA at 10 V. |
---|
Voltage input | Hight level: 4.5 to 30 VDC Low level: 0 to 2 VDC Input resistance: Approx. 4.7 kOhm |
---|
Applicable two-wire sensor | leakage current: 1.5 mA max. Switching capacity: 5 mA min. Residual voltage: 3.0 VDC max. Operating voltage: 10 VDC |
---|
Minimum input signal width | External reset: 1 ms/20 ms(selectable) |
---|
Standby time | 290 ms Max. |
---|
Control output (Contact output) | Output type: SPDT, SPST-NO Switching capacity: 3 A at 250 VAC/30 VDC, resistive load (cos phi=1) Minimum applicable load: 10 mA at 5 VDC (failure level:P reference value) |
---|
Display method | 7-segment negative transmissive LCD |
---|
Digit | 6 digit |
---|
Character height | Count value, Measurement value: 10 mm (Red, green or orange programmable) Zero suppression: Equipped Set value: 6 mm (Green) |
---|
Prescaling function | Provided (0.001 to 99.999) |
---|
Decimal point adjustment | Rightmost 3 digits |
---|
Key protection | Key protect Switch |
---|
Teaching function | Not provided |
---|
Batch counting function | Provided |
---|
Communications | Not provided |
---|
Memory backup | EEPROM (Number of rewite: 100000 times min., Service life: Approx. 10 years min.) |
---|
Surrounding air temperature | Operating: -10 to +55 CEL (Counters are mounted side by side: -10 to 50 CEL (with no icing or condensation)) Storage: -25 to +70 CEL (With no icing or condensation) |
---|
Ambient humidity | Operating: 25% to 85% Storage: 25% to 85% |
---|